Conventional Photoelectric Smoke and Heat Alarm
Conventional Photoelectric Smoke and Heat Alarm
+
  • Conventional Photoelectric Smoke and Heat Alarm
  • Conventional Photoelectric Smoke and Heat Alarm

Conventional Photoelectric Smoke and Heat Alarm

All of the SD119 series detectors meet the requirements of UL 268 and EN 54-7/5 for use in fire alarm signaling systems. They are intended for use in 2-wire/4-wire Class A or B supervised zone circuits. The SD119 series detectors are subject to panel compatibility limits and compliance with corresponding NFPA 72E standards, local codes, and ordinances.

Need to get samples first,  Contact US !

  • Product Introduction
  • Conventional Heat Detector

    All of the SD119 series detectors meet the requirements of UL 268 and EN 54-7/5 for use in fire alarm signaling systems. They are intended for use in 2-wire/4-wire Class A or B supervised zone circuits. The SD119 series detectors are subject to panel compatibility limits and compliance with corresponding NFPA 72E standards, local codes, and ordinances.

    The SD119 series include 2-wire and 4-wire detectors, which provide fast and reliable response for photoelectric smoke and heat (135°F) detection. While the smoke and heat detection circuits operate independently, their outputs being "OR' connected, The SD119 series detectors provide the fire detection performance by acting as a smoke sensor and/or a 13°F heat detector at the same location.

    Product Features:

    • 2 or 4 wire models
    • Advanced detection and discrimination algorithms
    • Easy installation and maintenance
    • Sleek low-profile housing design
    • Durable sensor head, no need for replacement
    • SMD circuit board design-satisfactory quality and reliability guaranteed
    • Integrated heat detector for SD119-2H and SD119-4H models
    • N/C (normal/close)-N/O (normal/open)selectable relay output
    • AR (Auto Reset) function for security systems (optional for 4 wire models) Sensor base option: standard and Shottky Diode
    • Five-year limited warranty

    The range includes:

    SD119- 2

    2 wire photoelectric smoke alarm

    SD119- 2- LED

    2 wire photoelectric smoke alarm with remote LED output

    SD119- 2H

    2 wire photoelectric smoke and heat alarm

    SD119- 2H- LED

    2 wire photoelectric smoke and heat alarm with remote LED output

    SD119- 4

    4 wire photoelectric smoke alarm (12/24/48VDC)

    SD119- 4B

    4 wire photoelectric smoke alarm with Buzzer (12/24/48VDC)

    SD119- 4AR

    4 wire photoelectric smoke alarm with auto-reset function (12/24/48VDC)

    SD119- 4ARB

    4 wire photoelectric smoke alarm with auto-reset function and Buzzer (12/24/48VDC)

    SD119- 4H

    4 wire photoelectric smoke and heat alarm (12/24/48VDC)

    SD119- 4HB

    4 wire photoelectric smoke and heat alarm with Buzzer (12/24/48VDC)

    SD119- 4HAR

    4 wire photoelectric smoke and heat alarm with auto-reset function (12/24/48VDC)

    Product Data:

    Smoke Sensitivity:

    0.08~0.2db/m(EN standard) or 0.98~4.0%/FT Obscuration (UL standard)

    Ceiling Spacing:

    50 foot rating for heat sensor

    Reset Voltage:

    less than 1 volt

    Reset Time:

    less than 1 second

    Alarm Indicator:

    LED continuously emitting red light

    Remote Output:

    25 mA max., diode gate

    Temperature Range:

    -10°C to 55°C, UL268 temperature: 0~37.8°C

    Permissible Current:

    80mA maximum

    Humidity:

    0 to 95% RH, no condensation or icing

    Alarm Contact:

    (for 4-wire) NO or NC Operation, Form A: 1.0A@30VDC/0.5A@125VAC

    Dimensions:

    100mm (dia) x 46mm (ht) with base

    Weight:

    130g/set with base

Conventional Photoelectric Smoke and Heat Alarm

All of the SD119 series detectors meet the requirements of UL 268 and EN 54-7/5 for use in fire alarm signaling systems. They are intended for use in 2-wire/4-wire Class A or B supervised zone circuits. The SD119 series detectors are subject to panel compatibility limits and compliance with corresponding NFPA 72E standards, local codes, and ordinances.

Need to get samples first,  Contact US !

Inquire Online

FREE QUOTE & INFORMATION REQUEST

Welcome Reachon Technology. Please fill out the form below to request a quote or to request more information about us and our products. Please be as detailed as possible in your message, and we will get back to you as soon as possible with a response. We're ready to start working on your new project, please contact us to get started now.