Conventional Heat Detector


All of the HD912 series detectors meet the requirements of UL521 and EN 54-5 for use in fire alarm signaling systems, which provide fast and reliable response for heat 57°C (135°F) or Rate-of-Rise detection, They are intended for use in 2-wire/4-wire Class A2 supervised zone circuits. The HD912 series detectors are subject to panel compatibility limits and compliance with corresponding NFPA 72E standards, local codes, and ordinances.

Conventional Photoelectric Smoke and Heat Alarm


All of the SD119 series detectors meet the requirements of UL 268 and EN 54-7/5 for use in fire alarm signaling systems. They are intended for use in 2-wire/4-wire Class A or B supervised zone circuits. The SD119 series detectors are subject to panel compatibility limits and compliance with corresponding NFPA 72E standards, local codes, and ordinances.

Dry-chemical Extinguisher


Non corrosive pull pin,Full hand grip for ease of operation,Waterproof stainless steel gauge,Anodized aluminum valve,Quick release hose and Cylinder with corrosion and impact resistant finish (red epoxy)

Carbon Dioxide Extinguisher


Chrome plated valve is precision machined from forged brass complete with stainless steel top and bottom handles

Universal wall hook and Universal wall bracket


Used for easy removal of fire extinguisher

Cart for 30 LB ABC Dry Chemical


Safely transports larger, heavier extinguishers 7 - 8" Diameter

Fire Extinguisher Cover


The interior coated polyester material provides added strength that helps prevent the covers from UV fading and cracking from harsh exposure to chemicals, salt spray and extreme temperatures

Wafer Style Butterfly Valves


BFV-W-4,BFV-W-6, BFV-W-8

Grooved Ends Butterfly Valves


BFV-DG-4,BFV-DG-6, BFV-DG-8

Grooved-End Ductile Iron Check Valve


Application: • Used in one-way flow pipeline to prevent the water from back flow • 350 PSI Working pressure • Installed in both Horizontal or Vertical Line with Upward Flow • Easier and Faster to Maintain and Install • Low Pressure Drop • All Stainless-Steel Wetted Parts to Provide Superior Corrosion • FM Approved & UL Listed

Vane Type Water Flow Switch


Application: • Designed to detect waterflow in a wet-pipe fire sprinkler system • Provide essential protection for fire wet sprinkler system • The adjustable retard delay range is 0 seconds to 90 seconds • FM Approved & UL/ULC Listed

Universal Manifold Check Assembly Valve


Universal Manifold Check Assembly Valve (UMC) includes Grooved butterfly valve, Grooved check valve, Water flow switch, Pressure gauge , Test and drain valve , Couplings and Pipes

Pressure Switch


Application: • Used to detect an increase and/or decrease from normal system pressure in automatic fire sprinkler systems. • FM Approved & UL/ULC Listed

Pressure Gauge


Application: Used for fire sprinkler systems and firefighting equipment Specially designed for fire sprinkler systems, suitable for air and water media (non-clogging and non-corrosive media) FM Approved & UL/ULC Listed

Water Motor Gong


Application: • Being self-contained and water operated, sounds continuously whenever the sprinkler system is activated • FM Approved & UL/ULC Listed